This Site is Best Viewed in IE5 and above with resolution 1024 X 768 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Monday, February 11, 2008
HT Distribution and Power Transformer Design Software
| |||||||||||||||||||||||||||||||||||||||||||||||||||||||
| |
HT Distribution and Power Transformer Design Software
Site By Thrifty SEO
How does transformer design software work? 2 - Still you have the "Manual" mode to change and fine tune your design as per your requirement (if desired), 3 - Change no. of HV coils/discs per limb, size of HV/LV conductor(s) - both round conductor and strip size, no. of parallel LV conductors, 4 - You can reset various clearances, change current density, conductor insulation as per your requirement and client specifications, 5 - Select HV winding type - Cross Over to Disc winding and vice -a - versa, 6 - Tapping details for OLTC and Off Load Tap Changer upto 25 steps. Enter any + step value through - step @ any % step value, 7 - You get values of Axial and radial forces developed in the windings during short circuits, temp gradients for HV and LV, Thermal Time Constant and ability to withstand shortcircuits with winding temperature rise, 8 - Pressed Steel Radiator (PSR) data calculation added you get automatic fixing dimensions of radiators - section width, CD and no. of fins. Options to select 226, 300 and 560 width sections. Tank drawing details are generated automatically. 9 - Feature added to get winding data for an old transformer 10 - GTP (Guaranteed Technical Particulars), Core details, core & winding assembly details, estimation and costing sheets are generated in the 'Word Format' for easy access, printing and sending the same via email to clients for approval, in house departments like design, QC, purchase, estimation, production, despatch. So this distribution and power transformer design software saves time, energy and revenue. A must key tool for transformer design and training professionals and engineering students.
Factors controlling and affecting the design of a transformer Principle of operation of a transformer "A transformer is a static machine which works on the principle of mutual induction. When a coil is placed in the vicinity of an other coil, an emf if generated in the coil with the change in rate of magnetic flux associated around the other coil." So all the transformer whether a HT transformer, a distribution transformer, power transformer, stepup transformer, stepdown transformer, auto transformer, furnance transformer, induction transformer, rectifier transformer, power supply transformer, auxillary transformer, control transformer, audio transformer, frequency transformer, EHT transformer, oil filled transformer, dry type transformer, current transformer, potential transformer, copper transformer, aluminium transformer, off load transformer and on load transformer all work upon the above said principle of operation of a transformer. The magnetizing core is a very essential part of a transformer. To get the preliminary dimensions of transformer core we first need to know the specifications of a transformer like - type of transformer (a number of transformer types are mentioned above), rating of transformer in KVA, number of phases of transformer, rated voltage for primary winding of transformer and secondary winding of transformer, the operating frequency of transformer, the vector group of transformer, short circuit impedence of transformer, no load losses of transformer, load losses of transformer, tapping requirements for transformer. The dimensions of the core of transformer are closely connected with the dimensions of other transformer parts like winding of transformer. The emf per turn of a transformer is one of the most important values defining not only the dimensions of a transformer, but the number of transformer winding turns too. This also influences the value of transformer short circuit impedence, the transformer weight and transformer losses etc.,. The transformer design flux density in a transformer leg depends upon the grade of CRGO core laminations that would be used in the transformer manufacture. For transformer core grades M2 to M6, the transformer design flux density is taken between 1.5 Tesla to 1.7 Tesla. Proper cooling methods must be adopted in higher rating distribution and power transformer. In HT transformer and EHT transformer, the insulation type and value should be calculated and choosen carefully. Total losses in a transformer are no load losses and load losses. As transformer is a static machine so no windage and frictional losses occure in a transformer. The temperature rise in a transformer is due to load conditions of transformer, surrounding environment of transformer, purity and cleaniness of transformer oil. The cooling surface of transformer tank must be calculated care fully to avoid over heating of transformer windings and transformer oil resulting in rise in transformer body temperature. The operational frequency of transformer also affects the temperature variations in transformer. So the transformer must be operated close to its designed frequency. The transformer temperature can also be reduced by care fully designing the transformer LT winding as to use many parallel insulated conductors instead of a single solid conductor. The HT winding transformer coils and LT winding transformer coils should have oil ducts in between layers to transfer heat generated in the HT winding transformer coils and LT winding transformer coils. The core laminations of a transformer are varnished and insulated from each other to reduce eddy current loss in a transformer. This also attributes in reduction of transformer temperature. The no. of transformer radiators are also calculated carefully. Forced air is also used to lower down the transformer temperature in case of large capacity power transformer. A transformer is provided with a temperature gause to measure and indicate the transformer oil temperature. In case of an abnormal condition a transformer protection relay called buchloze relay is provided in between the transformer tank and transformer conservator. All above design calculations are done by the transformer design software which also takes in consideration the tolerances, makes validations if some transformer design part goes wrong.
| ||||||||||||||||||||||||||||||||||||||||||||||||||||||
AC Electric Motor Design - Software
| AC Electric Motor Design Software Update: Download | Updated on: To be... | |
| AC Electric Motor Operational Manual: Download | ||
AC Electric Motor Design - Software
Softbit presents an easy way to design LT, 3 ph, TEFC, squirrel cage ac electric motors with the help of "AC Electric Motor Design Software". You just need to enter a few preliminary inputs and click a button. What you get is an output "Design Sheet" containing more than 100 output parameters required to build an ac squirrel cage electric motor. You can start to design from a small fractional horse power ac electric motor to a 50 hp ac electric motor using this design software. Higher hp modules are also available on request. You have the options to change any of the values from output design data to match your specifications and need. With the change in any of these values, the remaining parameters change automatically, without affecting the output design and performance of the motor.
What you can Change
You can change any parameter from the design data sheet like no. of slots, type of cage, material of cage conductor (Al or Cu), length of stator, bore of stator, core type / material, rotor dimensions, stator length, shaft diameter, shaft length, supply voltage etc.,. to get a better and most suited design for your requirement. Accordingly motor winding data will also change.
Why to change the output parameter
What ever results you get through this design software are as per calculations done using the formulae used to design a squirrel cage ac electric induction motor. Now suppose you get a rotor diameter as X and rotor length as Y but the job and place do not permit you to use these dimesions of rotor or say motor then you just change the value of either X or Y to best suit your requirement and all the related output parameters will change automatically. So you can customize the design as per yours , your client's or job's requirement.
Values you need to enter at the start
When you start designing a squirrel cage ac electric motor, certain preliminary values are required to be fed to the software to give the out put parameters. So you need to enter - capacity of motor in hp / kw, poles, supply voltage, rpm, frequency and certain more that the software will ask you at the time of start.
| |
Factors affecting the Design of an ac electric induction motor
"An electric motor converts electrical energy into rotating mechanical energy or an electric motor is a machine that converts electrical energy into rotating mechanical energy. AC electric motor works on the principle of electro - magnetic induction".
Design of an ac electric motor is directly affected by the length of the air gap. Ampere Conductors value also affects the design of an ac electric motor. The value of average flux density over the air gap of an ac electric motor also affects the design of an ac electric motor. The size or dimensions of an ac electric motor depend upon the speed of an ac electric motor. It can also be said that the volume of active parts of an ac electric motor varies inversely as the speed of an ac electric motor. The value of output co-efficient is directly responsible for the dimensions of an ac electric motor. In other words the volume of active parts of an ac electric motor is inversely proportional to the value of output co-efficient of the ac electric motor. The total flux around the armature (or stator of an ac electric motor) periphery at the air gap is called the total magnetic loading. While total electric loading is the total number of ampere conductors around the armature (or stator of an ac electric motor) periphery. Since the output coefficient of an ac electric motor is proportional to the product of specific magnetic and specific electric loading of an ac electric motor, we conclude that the size and hence the cost of ac electric motor decreases if increased values of specific magnetic and electric loading are used. The flux density in iron parts of an ac electric motor is directly proportional to the average flug density in the air gap of the ac electric motor. In a well designed ac electric motor the maxmium density occurs in the teeth of the ac electric motor and therefore let us relate the flux density in the teeth with flux density in the air gap of ac electric motor. Th magnetising current of an ac electric motor is directly proportional to the mmf required to force the flux through the air gap and the parts of the ac electric motor. The mmf required for the air gap of an ac electric motor is directly proportional to the gap flux density i.e. the specific magnetic loading of an ac electric motor. The consideration of magnetising current is very important in ac electric induction motor(s) as an increased value of magnetising current means of a low operating power factor of ac electric motor. Therefore specific magnetic loading in the case of ac electric induction motor(s) is lower than that in dc electric motor(s). The core loss in any part of the magnetic circuit of an ac electric motor is directly proportional to the flux density for which the ac electric motor is going to be designed. Thus a large value of specific magnetic loading in an ac electric motor indicates an increased core loss in ac electric motor and consequently a decreased efficiency of ac electric motor and an increased temperature rise of ac electric motor. In case of high frequency ac electric motor, specific magnetic loading must be reduced in order to get lower iron losses in ac electric motor so that reasonable values of efficiency may be maintained in an ac electric motor. The max. temperature rise of an ac electric motor is determined by the type of insulation material used in the ac electric motor. If the cooling co-efficient of the ac electric motor is small, a high value of specific loading may be used in the ac electric motor. The value of cooling co-efficient while designing an ac electric motor depends upon the ventilation conditions in the ac electric motor. An ac electric motor with better ventila- tion has a lower value of cooling co-efficient. If the current density in conductors of an ac electric motor and the slot space factor of ac electric motor are assumed constant, then specific electric loading of an ac electric motor is proportional to the diameter of the core of ac electric motor as depth usually depends upon the diameter of core of ac electric motor. Typical values of current density are in the range of 2 - 5 A/mm sq. in case of an ac electric motor. While desining an ac electric motor, temperature rise is usually 40 deg C for normal applications of ac electric motor and co-efficient is between 0.02 to 0.035 CW-m sq. The larger ac electric motor is intrinsically more efficient. As the size of an ac electric motor increases, better ventilation and cooling conditions have to be provided in the ac electric motor. Iron loss in an ac electric motor increases with increased value of air gap flux density. The value of air gap flux density of an ac electric motor determines the overload capacity of the ac electric motor. A large value of ac in an ac electric motor means that a greater amount of copper is employed in the ac electric motor. This results in higher copper losses in the ac electric motor and large temperature of embedded conductors in ac electric motor. A small value of ac should be taken for high voltage ac electric motor. And also higher value of ac in an ac electric motor, the lower would be the overload capacity of ac electric motor. For a normal design of an ac electric motor the dia of core of ac electric motor be so choosen that the peripheral speed of rotor of ac electric motor does not exceeds about 30 m/s. The three phases of an ac electric motor can be connected in either star or delta. The power factor of ac electric motor with agreater gap length is smaller. The harmonic fields in an ac electric motor are due to: i) windings of ac electric motor, ii) Slotting of ac electric motor, iii) Saturation of air gap of an ac electric motor and iv) Irregularities in the air gap of ac electric motor. The harmonic fields in an ac electric motor are responsible for increase in stray load losses in ac electric motor and increased ac electric motor heating. The choice of rotor slots of an ac electric motor is particularly important in the case of ac squirrel cage electric motors. The Cogging effect can be over come in an ac electric motor by the way that the number of stator slotes of ac electric motor should not be equal to the number of rotor slots of ac electric motor. Better to have 15 to 30 percent more or less rotor slots of ac electric motor than the number of stator slots of ac electric motor. The difference of stator slots of an ac electric motor and rotor slots of an ac electric motor should not be equal to 2p or 5p to avoid synchronous cups in ac electric motor. The difference between the number of stator slots of ac electric motor and rotorslots of ac electric motor should not be equal to 3p for 3 phase ac electric motor in order to avoid magnetic locking in ac electric motor. The difference between the number of stator slots of ac electric motor and rotor slots of ac electric motor should not be equal to 1, 2, (p+/-1) or (p+/-2) to avoid noise and vibrations in ac electric motor. The ac electric motor noise and vibrations, cogging effects in ac electric motor and synchronous cups in ac electric motor can be reduced or even entirely eliminated be skewing either the stator slots of ac electric motor or the rotor of ac electric motor. Also, in order to eliminate the effects of any harmonic in the ac electric motor, the rotor bars of ac electric motor should be skewed through an angle so that the bars lie under alternate harmonic poles of the polarity or in other words, bar must be skewed through two pitches in ac electric motor. A rotor of an ac electric motor with a high resistance has the disadvantage the I sq. R loss is greater in the ac electric motor and therefore its efficiency is lower under running conditions of ac electric motor. A rotor of an ac electric motor designed with a high value of current density results in high starting torque and a lower efficiency for the ac electric motor. The current density of rotor bars of an ac electric motor may be taken between 4 to 7 A/mm sq. The flux density in the rotor core of an ac electric motor is generally equal to the stator core density of ac electric motor. The total losses in an ac electric motor are equal to the sum of total copper losses in ac electric motor, iron losses in ac electric motor, friction losses in ac electric motor and windage losses in ac electric motor. A small value of leakage reactance of ac electric motor means that the power factor of the ac electric motor is good. The high starting torque of ac electric induction motor can be achieved by either using double cage rotor in ac electric motor or deep bar rotor in an ac electric motor. Design of shaft of an ac electric motor. The shaft of an ac electric motor must be strong enough throughout its section to withstand all loads causing residual strain. The diameter of shaft of ac electric motor in the bearings is less than the diameter under the armature of ac electric motor. Plain bearings are used for horizontal shaft ac electric motor and thrust bearings are used for vertical shaft ac electric motor.
| |
Electrical Panel Design Software - Industrial Power Control
(3 phase, 50/60 Hz electrical system, LT industrial power & control panel design)
Free 30 Days Trial Download (Full Version) - SoftPan(2D)![]()
| ||||||
One Software with multiple design features:
a)- Design Motor Control Center (MCC)
b)- Design Power Control Center (PCC)
c)- Design Desk Type Panels
d)- Design Instrumentation Panels
e)- Design Distribution & Metering DBs
f)- Design Feeder Pillars
g)- Design Bus Bar Trunking
h)- Draw Schematic Electrical Circuits
Why Our Software
| Latest Update - 1 - Now design PCC, MCC, Distributioin Centres, Distribution Boards, Machine ----Control Panels using PLCs, Instrumentation Panels, Desk Type Panels, --------Floor Type (slanted) Panels, Floor Type (plain) Panels. 2 - Get General Layout Drawings, Bill of Materials sheet, Estimation & Costing ----sheet, Single Line Diagrams, Complete Circuit Diagrams (semi automatic) ----generation. 3 - Labelling System (for accessories and controls) Added, 4 - Wiring (ferrul) Numbering System Added, 5 - Motor Starter Star - Delta Drawings added and auto selection of materials ----as per motor capacity and many more... |
Know more about the software...
Electrical Control Panel Design Software
3 phase industrial power control panel and distribution board designing is no more a tedious and time consuming job now. Get your industrial power panel and distribution board designed within minutes. Just drag the required switchgears, instruments, meters, indicating lamps, fuses & accessories into your work area and let your computer simulator design and calculate the various dimensions of your panel for you. Make changes in size if required, change placement of items to best suit you and again get a new design and dimension. No limit how many times you change the layout and you get the final designs.Simulator takes care of various clearances while you place an item in the template and calculates the final size by taking into consideration these clearances and other factors.
Panel accessories
Panel accessories like - Voltmeter, Ampere meter, Frequency meter, Red Indicator, Yelow Indicator, Blue Indicator, Hinge, Lock, Knob, Contactor, Relay, Timer, Insulator, Busbar - Support, Selector Switch, Control Fuse, Push Button, Earth Fault Relay, Over Current Relay, CT, Electric Motor Starter, Power Factor Meter can be dragged from the tool bar and placed upon the panel template as per the need of the design.
Types Of Panels You Can Design
With the help of this software now you can design any type of 3 phase industrial power and electrical control panels - be it a power control centre (PCC), a motor control centre (MCC), an electrical power distribution centre, electrical distribution board or an instrumentation panel. Design cubical power panels, desk type control and instrumentation panels, floor type control and instrumentation panels. A key tool to design 'Contorl & Relay Panels' using PLCs and SCADA system.
Draw Electrical Circuit![]()
The software lets you draw any type of complecated electrical power and control circuit/diagram. You draw horizontal and vertical lines and put electrical symbols upon the lines to complete your electrical (power or control) circuit. Cross over points are automatically converted into shorting-links or may be changed to jumpers or vise-a-versa. The software contains almost all the symboles in its library required to generate electrical power and control circuits. Label all the electrical symboles through a pop up text box - just enter the name/specification of the item and put it near the the symbol. Put ferrul numbering on each wire as per your convenience and requirement. Give color to all the lines as red (R), yellow (Y) and blue (B). Default line color is black i.e., neutral (N). Select line thickness to differenciate between power and control wiring. Rotate electrical symboles by 90 deg or back to best suit the placement upon the power lines. Delete any electrical symbol or power line with right mouse operation. So this software can generate elctrical power and control circuits in semi automatic mode.
Single Line Diagram
Single Line wiring diagram is generated automatically.
Bill Of Materials
What ever you add to your panel or electrical circuit, every thing is added to bill of material sheet automatically. If you delete an item it is removed from the sheet itself.
Estimation & Costing
You get a detailed estimation and costing detail in the word formate for easy printout and distribution. Change item cost, panel board painting and fabrication cost, bus bar cost, labour cost, margin profit as per your system and set up.
Printouts
Take printouts of the complete design along with detailed bill of materials, estimation & costing sheet, general layout, single line diagrame (auto-generation) and finally complete circuit diagram (semi-auto mode). When you have completed the design part and would like to know the cost of your panel, options are there to see the individual costs of busbars and panels.
Free world wide updation support
This software comes with free online updation support for one year. So where ever you are located around the world, you just need a net connectivity to get free updation.
Site By Thrifty SEO
| |
Softbit Computer Simulation
| Electrical Panel - more... | Electric Motor - more... | Distr. Transformer - more... |
| Product Code SCS-MD 177 Single License Price: US $ 2,725 (Indian Rs.1,25,000/-) | Product Code : SCS-TD2K Single License Price: US $875 (Indian Rs.37,500/-) other options... | |
| | | |
| |
With the help of these simulations you can verify virtually various parameters of a machine before you start manufacturing it. So you can change the values to get desired results on the screen. You will have the options to select the constants and variables before you start to work upon a simulation. Now enter the output values of the machine under study and you will get the all design parameters of the machine.
The SCS are designed for the engineers with an aim to get high productivity and easy to learn features, with full documentation that includes extensive information on machine theory and design. Machine design with SCS is interactive and fast. However, the SCS software does not do the engineer's job. It is simply a specialized calculating tool to assist the design engineers with initial sizing and preliminary design of an electric machine by providing a simple intuitive interface and quick simulation.
Site By Thrifty SEO
| |
Cutomised Software Solutions
Cutomised Software Solutions
Softbit is fully equipped to develop any sort of CAD/CAM based engineering design applications using VB6 at front end with back end support of VC, OpenGL, MS or other DataBases.
Our development team is consists of technically qualified (electronics & communications, electrical, instrumentation, science graduates) and experienced engineers.
Remote Access Data Logger:
Our team now-a-days is working on "Remote Access Data Logger", to be used for monitoring and protection of electrical systems.
Data loggers would be installed with different electrical systems/machines to be monitored and connected to a local PC with global remote access and control.
The electrical parameters would be recorded by the data loggers and can be downloaded to a local PC. The PC would have an interface to control and reset various functions of the data logger. The data logger would be connected to a server through a modem for storing data to the server for remote access by the user. Data would be stored to the server at regular intervals. The user can access his/her electrical system/machine in any part of the world through an internet connection on his/her PC/laptop. All the data can be downloaded to the PC/laptop. User can switch on or off the system/machine if he/she finds any abnormality. So using our data loggers one can access his/her electrical systems/machines form any part of the world.
To let you know about the qualilty and type of development work we have undertaken so far, we are mentioning a few of them as under. You can also download demos of these from our demo download page.
Site By Thrifty SEO
Affiliates : Business Partners
We will be appointing minimum 4 to a maximum 12 affiliates (business partners) in every country depending upon the demand and size of country.
The affiliate's (business partner) association with softbitonline can be of free or paid, in what ever way an affiliate (business partner) wishes to join.
Affiliates (business partners) shall take care of people who are willing to buy our software products. They will be responsible for all inquiries they get directly from their area or one that is forwarded from softbitonline. Affiliates (business partners) shall be responsible for promoting, generating inquiries, giving demonstration, taking care of the payment part and providing necessary after sales service and support to clients for our various software packages.
Please read below the types of affiliation (business partnership) programmes softbitonline offers at present:
S.no.
Programme
Joining Fee
Earning
Target Earning
Our Support
1-
Affiliate
NIL
15%
5%
online
2-
Affiliate
US $4,500.00
35%
10%
online + Full versions of software for demo
Target Earning: Affiliates giving an annual business of sale worth more than US $ 4,50,000.00 for of design softwares / simulations shall be entitled for "Target Earning".
Why Our Affiliation is worth joining:
Our experience (along with online site statics) has shown that there is a great demand for design and training softwares in industries, technical and engineering colleges. We get around 150 (approx) uniuque visitors with particular keywords against which they are looking for certainl special sites. Our daily page load rate is 700 (approx). We are generally being asked for our local or country representative. To full the requirement of our clients we need affiliates (business partners).
Keywords:
Keywords which bring the visitors to our site are - ac electric motor design, electric motor design, electrical control panel design, electrical control panel, distribution transformer design, transformer design software. These are very basic key words but we get visitors from other keywords also.
Our rank in Google and Yahoo:
We are almost on the first page and in first 5 positions. Thanks to google and Yahoo SEO technology. We have achieved this position with hard work, dedication and deep study and knowledge of our products.
General Terms & Conditions:
1. Affiliate membership acceptance is totally on softbitonline management approval.
2. Joining fee once paid shall not be refunded in any case.
3. Affiliates shall be responsible for promoting, demos, taking orders, getting payments from prospective clients of their area.
4. Order acceptance in any case shall be at the sole discretion of softbitonline.
5. All affiliates (business partners) would be required to place a log of softbitonline on their website home page. It is mandatory.
6. Softbitonline has the right to amend the terms & condtions for affilliate any time without informing to them and those shall be binding to all affiliates uncondtionally. Of course an intimation to all affiliates shall be sent for knowlede and records.
To apply for membership, more details please contact at - contact
Site By Thrifty SEO
OLTC AVR & RTCC Panel
| Onload Tap Changer (OLTC) is used with higher capacity transformers where HT side voltage variation is frequent and a nearly constant LT is required. OLTC is fitted with the transformer itself. Multiple tappings from HV windings are brought to the OLTC chamber and conacted to fixed contacts. Moving contacts rotates with the help of rotating mechanism having a spindle. This spindle can be rotated manually as well as electrically with a motor. Motor is connected in such a way that it can rotate in both the directions so as to rotate the OLTC contacts in clockwise and anticlock-wise direction. Two push buttons are fitted on the LCP (local control panel) to rotate the motor and hence the OLTC contacts in clockwise and anti-clockwise direction. This movement of contacts thus controls the output LV voltage of the transformer. So rotating of OLTC contacts with spindle or push buttons in this way is a manuall process. In case this process of rotating the OLTC contacts and hence controlling the LV side voltage is to be done automatically then a RTCC (Remote Tap Changer Controller) is installed with the transformer HT Panel. The RTCC sends signals to LCP and LCP in turn rotates the motor as per the signals received from the the RTCC.
Automatic OLTC Panel consists of a LCP & a RTCC. System uses an AVR (AVR-MA9) to sence the LV voltage and a comparator circuit to compare the sencing voltage with a preset value. Any difference in two sends a corresponding signal to OLTC pane to lower or raise the LV voltage of transoprmer. The OLTC control panel also has the provision to operate two or more transformers in parallel. One transformer is taken as the master and the remaining as the followers so that they follow the master's LV voltage set values. An OLTC control panel panel is fitted with various indications to visually show the various operations being performed by the OLTC as forward and reverse movement of OLTC contacts, upper limit and lower limit indications, fault indications, interlocking indications between manual and automatic mode of the OLTC and many more. | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| Working of OLTC AVR - MA9 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| The Automatic Voltage Regulator Relay - AVR-MA9, is a totally microprocessor based relay that controls the arm movement with the help of high torque motor (OLTC and motor are not parts of the AVR supply). It also indicates the line voltage, line current, load on the transformer, apparent and reactive powers, system frequency and power factor. The AVR can be set to "Auto" or "Manual" mode. In "Auto" mode the AVR controls and maintains the transformer LV voltage as per the pre set value automatically. It sences the variations in LV voltage for a pre-set time delay and brings the voltage to normal value by changing the tap position of OLTC with the help of high torque motor. In "Manual" mode the LV voltage can be controlled through low/high push buttons which are fitted along with OLTC - LCP (Local Control Panel). Up and down movement of OLTC motor is indicated with the glow of LEDs fitted on the AVR and on the OLTC - LCP. This AVR can be used with any type of OLTC as it has to control the movement of motor which is connected with the arm that moves the contacts of the OLTC. The LCP is generally fitted near the OLTC or upon the OLTC box while the RTCC is fitted with the HT panel of the transformer. PC/Laptop Connectivity of OLTC-AVR: | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| Please contact us with your requirement, more details and pricing on OLTC - AVR at - info@softbitonline.com | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
AVR
| | Hynetic™ AVR (Alternator Voltage Regulator) State of Manufacture : New Delhi - India Exporting to: Australia, England, Singapore and USA Available AVR Models: Hynetic - ECO & Hynetic - U:1000 | ||||||||||||||||||||||||||||||||||||||||||||||||||||||
| Hynetic™AVR - A universal AVR that can be used with any make of alternator / ac generator upto 1500 KVA capacity i.e., it can be used with JYOTI, NGEF, CROMPTON, KIRLOSKER, STEMFORD, MARCON, BRUSHCH, LEROY SOMER, AVKC or any other brushless alternator having Excitation parameters within its limits. Customized AVR/SEU - Softbit can also design & develop customized high current AVRs & Static Excitation Units (SEU) as per your requirements. No problem what ever DC voltage and excitation current you need. Just send your requirent for a quote.
Technical Specifications - AVR (Alternator Voltage Regulator):
NOTE
| |||||||||||||||||||||||||||||||||||||||||||||||||||||||
Data Logger
Wireless Remote Monitoring & Control | |
| Remote Intel-Visor i.e. Remote Intelligent Supervisor is a remote wireless data logger for industrial & process automation, GPRS/GMS based SCADA solutions with 'Plug & Play' feature. Softbit has launched a range of remote data loggers for wireless industrial & process automation. This wireless remote data logger can be used for real time data acquisition & control of remote installed electrical systems, HT/LT electric motors, HV/LV transformers, generators, HT/LT distribution panels, boilers or any electrical | |
| machine/system. This micro-processor based wireless remote data logger works on "Plug & Play" methodology i.e. this comes fully pre-programmed and you only need to connet it with a machine to be monitored from remote. | |
Using the internet as medium of communication, the wireless remote data logger is connected to a PC/Laptop through USB or RS-232 communication port and sensing wires from a machine are connected to the data logger to send signals to data logger. The data logger after processing these signals displays various electrical parameters of the machine first at local PC/Laptop and simultaneously send these parameters to a remote server. These electrical parameters once stored on the remote server can be accessed through any other PC connected to internet. The access is protected through login password. So only an authorised person can view the data and electrical parameters of a remote machine. Switching operation of remote machine can also be performed through remote PC by entering into the user accoount through login password. An exceptionally low cost wireless GPRS/GMS based SCADA solution for remote industrial automation.
Advantages of Wireless Remote Data Logger:![]()
Following are the main advantages of Remote Data Logger. An exceptionally low cost wireless GPRS/GMS based SCADA solution for remote industrial automation:
a)- Energy Conservation
b)- Condition Monitoring of Machines
c)- Remote Monitoring & Control
d)- Power Management
e)- Industrial Automation
f)- Enterprise Integration
If you are concerned with any of the above issues then its the best time to install Wireless Remote Data Logger.
Applications of Wireless Remote Data Logger:![]()
Remote Data Logger has applications in every type of industry where continuous data acquisition & monitoring is required. An exceptionally low cost wireless GPRS/GMS based SCADA solution for remote industrial automation.
These remote data loggeres find applications in:
a)- Chemical Industry,
b)- Electricity Generation & Utility,
c)- Military & Defence,
d)- Manufacturing & Process Industry
e)- Medical Sector,
f)- Mining & Extraction Industry,
g)- Oil, Gas & Petroleum Industry
The most important application of remote data logger is energy management by keeping a vigil on electrical energy being used and there by managing it.
Who can use the Wireless Remote Data Logger:![]()
Remote Data Logger can be used by a wide spectrum of users both from industry as well as engineering institutions.
These remote data loggeres can be used by:
a)- Electrical Consultants & Advisors,
b)- Electrical Engineers,
c)- Production Engineers,
d)- Maintanance Engineers,
e)- Engineering Management Cadre,
f)- Technical Management Cadrey,
g)- Engineering Students,
h)- Research & Development Engineers for data analysis,
i)- Survey Engineers for planning & implementaions,
j)- Senior Management People,
k)- Field Engineers,
l)- Marketing Engineers
Equipments and Services those can be monitored & controlled with Wireless Remote Data Logger:![]()
Remote Data Logger can be connected with any of the following equipments to monitor & control it from remote.
The equipments & services are::
a)- Power Generation (Hydel, Nuclear, Gas),
b)- HT/LT Power & Distribution Transformers,,
c)- Circuit Breakers,
d)- Switchgear,
e)- Medical Equipments,
f)- HT/LT Electric AC/DC Motors,
g)- HT/LT AC/DC Generators,
h)- Any machine that operates on electricity,
i)- Whole Electrical Systems,
j)- Boilers,
k)- Furnaces
| Input Voltage | 90 - 250 VAC with Neutral |
| Phase | 3 |
| Current Sensing | Through Metering CT - Any Ratio (CT ratio can be configured) |
| Analog Input | 2 nos. |
| Digital Input | 1 no. |
| Relays | 5 nos. |
| Relay rating | @ 10 Amps |
| Relay Contacts | 1NC + 1NO |
| Max. Sensor Inputs | 2 nos. per Logger (Add on available) |
| LCD Display | 16 x 2 |
| Temperature | -10 - +75 deg Celcius |
| Enclosure Size | 160mm X 110mm X 70mm |
| Weight | 0.950 Kg (with enclosure) |
Input Sensors for Wireless Remote Data Logger (RMC-05):
A wide variety of sensors can be connected to the remote data logger as these can be easily configured with the data logger (RMC-05). Any two of the following analog sensors and any one of the digital sensors can be used with the Remote Data Logger. These sensors are to be purchased separately.
| S No. | Analog Sensors | Digital Sensors |
| 1 | Temperature | Photo Cell |
| 2 | Noise | Infra-Red |
| 3 | Pressure | Tilt-Sensor |
| 4 | Fluid Level | |
| 5 | Vibration | |
| 6 | Flow Rate | |
Working of Wireless Remote Data Logger:![]()
The working of remote data logger can easily be explained by spliting it into three parts:
1)- Base Unit i.e., the Remote Data Logger itself,
2)- Local PC Interface i.e.. local computer system to which the data logger is connected,
3)- Remote Web Account i.e., remote computer system for remote access of data logger
This is a shared hosting type remote data logger with 2 nos. of analog inputs and 1 no of digital input. Sharing does not mean any data sharing or revealing any of your data components to a third party, its just to bring the cost of remote data logger and its usage expences to a very minimum. Your data is 100% secure and safe and no other one can view it without entering into your password protected web account.
| Local PC Interface | Remote Data Logger | Remote Web Account |
![]() |
Installation & Commissioning of Wireless Remote Data Logger:![]()
Our Remote Data Logger comes fully pre-programmed and the user has to do nothing. Just make the connections as explained in the operational manual and start using it. Any maintenance or production engineer/foreman having basic knowledge of electrical systems can easily make the connections of remote data logger with any machine that operates on electricity.
Once the remote data logger is connected & energized, it starts sending signals to PC/Laptop. The various electrical parameters of machine (which is connected to data logger) can be read on the "Local PC Interface" (Local PC Interface can be downloaded free from our website). And if this PC/Laptop is connected to internet, all the acquired parameters are sent to remote server for remote monitoring.
And if the user has activated his/her "Remote Web Account" then all the parameters can be monitored from a remote PC/Laptop. User can also do the switching operations from the remote PC/Laptop. An exceptionally low cost wireless GPRS/GMS based SCADA solution for remote industrial automation.
System Voltage - Wireless Remote Data Logger
Remote Data Logger can be used with LT/HT/EHT electrical systems/machines because you can you can give the input voltage at the input terminals directly (90 - 250 VAC) or through a PT. But the values can be read read as full values as - 433V, 11000V, 22000V, 33000V or 66000V.
In the same way any value of current can be read through data logger using suitable CTs. So you can connect a fractinal horse power to 5000 HP or more capacity electric motor (or any electrical machine) with the data logger. But again the values can be read read as full values as - 0 to 7500 Amps or more.
Models of Wireless Remote Data Logger:![]()
At present two model are available and viz.,. -
1)- Model: RMC-05 &
2)- Model: RMC-05(GPRS)
An exceptionally low cost wireless GPRS/GMS based SCADA solution for remote industrial automation.
![]() | This remote data logger requires an intermediate PC/Laptop to get connected to Internet i.e., this remote data logger sends signals to server through a PC or a Laptop. The data logger is connected to PC/Laptop through RS-232 or a USB port. Configuration can be done directly from the data logger from feather touch keypad. Otherwise, one can also use the PC keyboard to configure the data logger. |
Model: RMC-05(GPRS)
![]() | This model of wireless remote data logger gets connected to internet through GPRS (General Packet Radio Service) which is the world's most ubiquitous wireless data service. This service is available now with almost every GSM (Global System for Mobile communications) network. Using this latest technology, the best way of connecting to internet is through a "Data Card". Today, most of the mobile phone service provider are providing "Data Cards" for wireless internet accessibility. |
| So you can use any data card available in your area. In India Reliance, Air-Tel, Tata, Hutch have already providing such data cards for wireless internet. Just plug in the data card to remote data logger through USB port and its ready for use. So no intermediate PC or Laptop. | |
We are well equipped to provide live online training and support. In case you find any difficulty in using the remote data logger, we will take control of the remote data logger in real time from our place and will provide you necessary online support.
Warranty for Wireless Remote Data Logger:
We provide full one year warranty for all our data loggers sold, received at our end.
Live Demo of Wireless Remote Data Logger:
Sign up - Membership to see live demonstration of one of the remote data loggers installed at our client sites.
Pricing Information of Remote Data Logger:
Please contact us with your requirement for more details and pricing at -
info@softbitonline.com
Site By Thrifty SEO
Softwares

Cutomised Software Solutions
Softbit is fully equipped to develop any sort of CAD/CAM based engineering design applications using VB6 at front end with back end support of VC, OpenGL, MS or other DataBases.
Our development team is consists of technically qualified (electronics & communications, electrical, instrumentation, science graduates) and experienced engineers.
Remote Access Data Logger: 





Our team now-a-days is working on "Remote Access Data Logger", to be used for monitoring and protection of electrical systems.
Data loggers would be installed with different electrical systems/machines to be monitored and connected to a local PC with global remote access and control.
The electrical parameters would be recorded by the data loggers and can be downloaded to a local PC. The PC would have an interface to control and reset various functions of the data logger. The data logger would be connected to a server through a modem for storing data to the server for remote access by the user. Data would be stored to the server at regular intervals. The user can access his/her electrical system/machine in any part of the world through an internet connection on his/her PC/laptop. All the data can be downloaded to the PC/laptop. User can switch on or off the system/machine if he/she finds any abnormality. So using our data loggers one can access his/her electrical systems/machines form any part of the world.
To let you know about the qualilty and type of development work we have undertaken so far, we are mentioning a few of them as under. You can also download demos of these from our demo download page.
Softbit Training Simulations - CD-ROMs
| | | |
| AC Generator Training Learn the intricacies of an ac generator operation and its construction details.You would be thrilled by the amazing animation that teach you in a most natural way.Maintenance, overhaul and routine trouble shooting activities have also been discussed in great details. | AC Electric Motor Training Learn the fundamentals of the most frequently used machine in plants and non-commercial installations. Get a complete picture of the operation, maintenance and trouble shooting procedures. Diagrams and animations adequately support the text. | Diesel Engine Training Diesel engines are the prima movers of all the industrial conglomerates. No one depends on the power supplied by the electricity authority, at least in the context of industrial operations. Get inside a diesel engine and learn about its various parts (with minute details). |
| AC Generato Training- more... | AC Electric Motor Training - more... | Diesel Engine Training - more... |
| Single License Price: US $ 125 Product Code : AT 017 (Indian Rs.5,500/-) | Single License Price: US $ 125 Product Code : AT 018 (Indian Rs.5,500/-) | Single License Price: US $ 125 Product Code : AT 019 (Indian Rs.5,500/-) |
| | | |
These Technical Multimedia Interactive Presentations on CD-ROMs are very much useful for conducting in house training programmes. Industries can use these CD-ROMs for training, knowledge enhacement of their staff at operational, junior and senior levels. Engineering professionals and and students will also find these CD-ROMs a unique tool in acquiring practical knowledge. A must for technical libraries.
Site By Thrifty SEO
| |
Frequently Asked Questions
| 1. | What are these Training Modules? |
| 2. | Are these ready made or tailor made? |
| 3. | Can we run these presentations on VCD player? |
| 4. | Who can use these Training Modules? |
| 5. | What is a computer simulation? |
| 6. | Do we need a special PC to run the training modules and design simulations? |
| 7. | I would like to get a custom made training module on a machine of my interest. Can you develop one for me? |
| 8. | Is it necessary to connect to your online data base every time we use any of your training or design simulators? |
| 9. | What about the updated versions of design simulations and training modules. Do you charge extra to give updation supports? |
| 10. | How do we get login details to get connected to online data base? |
| 11. | I have a different query that is not answered here any where. What to do? |
| | |
| | |
| | |
| 1. | What are these Training Modules? These are Technical Multimedia Interactive Computer Based Presentations being used for conducting in-house training in industries and engineering colleges. |
| | |
| 2. | Are these ready made or tailor made? These are ready mede presentations on CD-ROMs for sale. |
| | |
| 3. | Can we run these presentations on VCD player? No. These can only be run on computers with a CD-ROM drive. |
| | |
| 4. | Who can use these Training Modules? All engineering professionals related with design, production, plant maintenance and trouble shooting can find these training modules a worth having with them and using. Apart from this students from technical colleges will find these training modules an essential learning tool to get practical knowledge. Libraries of engineering colleges will add a feather to their shelves by keeping these for students. People in the field of training sector and conducting technical seminars, workshops, classes will also get benefitted fom these training modules as they need not to make any prsentation for each and every product as they can get these ready made with abondace of rich graphics, text, voice over, music, 2D / 3D models of machines. |
| | |
| 5. | What is a computer simulation? Computer simulation is a programme which can run on a PC and training purpose and design purpose. We can get various sets of final output parameter by changing the input parameters and hence studying the results for getting a better design of a machine before we go for a prototyping. This saves lot of time, energy and money wasted in making prototypes first and then studying the end results later on. Though we can not get 100% final results through a simulator untill we make a prototype but much of the repeat steps are over come and we achieve the final in one or two attempts. |
| | |
| 6. | Do we need a special PC to run the training modules and design simulations? Absoluetly Not. You can run these training modules and design simulation on any PC with multimedia support and having minimum configuretaion of - Pentium III, 600 + MHz, 128 MB RAM, 10 GB or 20 GB storage. |
| | |
| 7. | I would like to get a custom made training module on a machine of my interest. Can you develop one for me? You are always welcome with your request and it will be our pleasure to work upon that. If it will be of major demand and can fetch us a good business then we will charge our tagged price from you and if it is exclusively developed for you with all rights owned by you then the total project cost shall be borne by you only. |
| | |
| 8. | Is it necessary to connect to your online data base every time we use any of your training or design simulators? No. Not even once. It is only a support service which is free for first year and chargable annually there after. This data base only supports and helps you by providing ready made and refined data for your design simulations which otherwise you shall have to creat - a tedious and time consuming exercise. We have a full fledged team for this exclusive purpose. |
| | |
| 9. | What about the updated versions of design simulations and training modules. Do you charge extra to give updation supports? Updation support for the first year if absoluetly free. You can get the updations downloaded by connecting to your account by providing login details. |
| | |
| 10. | How do we get login details to get connected to online data base? All esteemed buyers will connect to the online data base through their product lisence no. (as login ID) which you get with every design simulation. |
| | |
| 11. | I have a different query that is not answered here any where. What to do? You are always welcome to contact us via Emai - info@softbitonline.com or Phone:+91-11-25438952 |
| Registered Office - INDIA |
| Softbit Technologies Pvt. Ltd. |
| USA - Representation |
| Softbit Technologies |
| Europe - Representation |
| Mr. Dharmender Pal Singh Email: europe@softbitonline.com |
Terms
| |||||
| |||||
| Business Deals | |||||
| (1). Softbit has engineering products, technical books, old machinery and services (software's) online for selling to global customers. You can choose any method offline payment or online payment system to make payments for selected products / services you wish to buy. | |||||
To keep you well informed and happy, Softbit.net welcomes your comments and questions via e-mail. All your queries would be answered as quickly and thoroughly as possible.
Management & Staff
Softbit Technologies Pvt. Ltd., New Delhi India
E-mail : info@softbitonline.com
© 2004 - 2005 All Rights Reserved SOFTBIT TECHNOLOGIES PVT LTD.
Site By Thrifty SEO